EEPROM Library
EEPROM data memory is available with a number of AVR family. The mikroBasic PRO for AVR includes a library for comfortable work with MCU's internal EEPROM.
Important :
EEPROM Library functions implementation is MCU dependent, consult the appropriate MCU datasheet for details about available EEPROM size and address range.
Library Routines
EEPROM_Read
| Prototype |
sub function EEPROM_Read(dim address as word) as byte |
|---|---|
| Returns |
Byte from the specified address. |
| Description |
Reads data from specified Parameters :
|
| Requires |
Nothing. |
| Example |
dim eeAddr as word temp as byte ... eeAddr = 2 temp = EEPROM_Read(eeAddr) |
EEPROM_Write
| Prototype |
sub procedure EEPROM_Write(dim address as word, dim wrdata as byte) |
|---|---|
| Returns |
Nothing. |
| Description |
Writes Parameters :
Note :
Specified memory location will be erased before writing starts.
|
| Requires |
Nothing. |
| Example |
dim eeWrite as byte
wrAddr as word
...
eeWrite = 0x02
wrAddr = 0xAA
EEPROM_Write(wrAddr, eeWrite)
|
Library Example
This example demonstrates using the EEPROM Library with ATmega16 MCU.
First, some data is written to EEPROM in byte and block mode; then the data is read from the same locations and displayed on PORTA, PORTB and PORTC.
program EEPROM
dim counter as byte ' loop variable
main:
DDRA = 0xFF
DDRB = 0xFF
DDRC = 0xFF
for counter = 0 to 31 ' Fill data buffer
EEPROM_Write(0x100 + counter, counter) ' Write data to address 0x100+counter
next counter
EEPROM_Write(0x02,0xAA) ' Write some data at address 2
EEPROM_Write(0x150,0x55) ' Write some data at address 0x150
Delay_ms(1000) ' Blink PORTA and PORTB diodes
PORTA = 0xFF ' to indicate reading start
PORTB = 0xFF
Delay_ms(1000)
PORTA = 0x00
PORTB = 0x00
Delay_ms(1000)
PORTA = EEPROM_Read(0x02) ' Read data from address 2 and display it on PORT0
PORTB = EEPROM_Read(0x150) ' Read data from address 0x150 and display it on PORT1
Delay_ms(1000)
for counter = 0 to 31 ' Read 32 bytes block from address 0x100
PORTC = EEPROM_Read(0x100+counter) ' and display data on PORT2
Delay_ms(100)
next counter
end.
Copyright (c) 2002-2012 mikroElektronika. All rights reserved.
What do you think about this topic ? Send us feedback!