SPI Lcd8 (8-bit interface) Library
The mikroBasic PRO for ARM provides a library for communication with Lcd (with HD44780 compliant controllers) in 8-bit mode via SPI interface.
For creating a custom set of Lcd characters use Lcd Custom Character Tool.

- When using this library with ARM family MCUs be aware of their voltage incompatibility with certain number of Lcd modules.
So, additional external power supply for these modules may be required. - The library uses the SPI module for communication. The user must initialize the appropriate SPI module before using the SPI Lcd8 Library.
- For MCUs with multiple SPI modules it is possible to initialize all of them and then switch by using the
SPI_Set_Active()
routine. See the SPI Library functions. - This Library is designed to work with the mikroElektronika's Serial Lcd/Glcd Adapter Board pinout, see schematic at the bottom of this page for details.
Library Dependency Tree

External dependencies of SPI Lcd Library
The implementation of SPI Lcd Library routines is based on Port Expander Library routines.
External dependencies are the same as Port Expander Library external dependencies.
Library Routines
SPI_Lcd8_Config
Prototype |
sub procedure SPI_Lcd8_Config(dim DeviceAddress as byte) |
---|---|
Description |
Initializes the Lcd module via SPI interface. |
Parameters |
|
Returns |
Nothing. |
Requires |
External dependencies are the same as Port Expander Library external dependencies.
|
Example |
Stellaris' Port Expander module connections dim SPExpanderRST as sbit at GPIO_PORTA_DATA0_bit dim SPExpanderCS as sbit at GPIO_PORTA_DATA1_bit dim SPExpanderRST_Direction as sbit at GPIO_PORTA_DIR0_bit dim SPExpanderCS_Direction as sbit at GPIO_PORTA_DIR1_bit ' End Port Expander module connections ... ' If Port Expander Library uses SPI1 module SPI1_Init() ' Initialize SPI module used with PortExpander SPI_Lcd8_Config(0) ' initialize lcd in 8-bit mode over spi interface STM32' Port Expander module connections dim SPExpanderRST as sbit at GPIOB_ODR.B0 SPExpanderCS as sbit at GPIOB_ODR.B1 ' End Port Expander module connections ... ' If Port Expander Library uses SPI1 module SPI1_Init() ' Initialize SPI module used with PortExpander SPI_Lcd8_Config(0) ' initialize lcd in 8-bit mode over spi interface |
Notes |
None. |
SPI_Lcd8_Out
Prototype |
sub procedure SPI_Lcd8_Out(dim row, column as byte, dim byref text as string) |
---|---|
Description |
Prints text on Lcd starting from specified position. Both string variables and literals can be passed as a text. |
Parameters |
|
Returns |
Nothing. |
Requires |
Lcd needs to be initialized for SPI communication, see SPI_Lcd8_Config routine. |
Example |
' Write text "Hello!" on Lcd starting from row 1, column 3: SPI_Lcd8_Out(1, 3, "Hello!") |
Notes |
None. |
SPI_Lcd8_Out_Cp
Prototype |
sub procedure SPI_Lcd8_Out_CP(dim byref text as string) |
---|---|
Description |
Prints text on Lcd at current cursor position. Both string variables and literals can be passed as a text. |
Parameters |
|
Returns |
Nothing. |
Requires |
Lcd needs to be initialized for SPI communication, see SPI_Lcd8_Config routine. |
Example |
' Write text "Here!" at current cursor position: SPI_Lcd8_Out_Cp("Here!") |
Notes |
None. |
SPI_Lcd8_Chr
Prototype |
sub procedure SPI_Lcd8_Chr(dim row, column, out_char as byte) |
---|---|
Description |
Prints character on Lcd at specified position. Both variables and literals can be passed as character. |
Parameters |
|
Returns |
Nothing. |
Requires |
Lcd needs to be initialized for SPI communication, see SPI_Lcd8_Config routine. |
Example |
' Write character "i" at row 2, column 3: SPI_Lcd8_Chr(2, 3, "i") |
Notes |
None. |
SPI_Lcd8_Chr_Cp
Prototype |
sub procedure SPI_Lcd8_Chr_CP(dim out_char as byte) |
---|---|
Description |
Prints character on Lcd at current cursor position. Both variables and literals can be passed as character. |
Parameters |
|
Returns |
Nothing. |
Requires |
Lcd needs to be initialized for SPI communication, see SPI_Lcd8_Config routine. |
Example |
Print “e” at current cursor position: ' Write character "e" at current cursor position: SPI_Lcd8_Chr_Cp("e") |
Notes |
None. |
SPI_Lcd8_Cmd
Prototype |
sub procedure SPI_Lcd8_Cmd(dim out_char as byte) |
---|---|
Description |
Sends command to Lcd. |
Parameters |
|
Returns |
Nothing. |
Requires |
Lcd needs to be initialized for SPI communication, see SPI_Lcd8_Config routine. |
Example |
' Clear Lcd display: SPI_Lcd8_Cmd(_LCD_CLEAR) |
Notes |
Predefined constants can be passed to the routine, see Available SPI Lcd8 Commands. |
Available SPI Lcd8 Commands
SPI Lcd8 Command | Purpose |
---|---|
_LCD_FIRST_ROW | Move cursor to the 1st row |
_LCD_SECOND_ROW | Move cursor to the 2nd row |
_LCD_THIRD_ROW | Move cursor to the 3rd row |
_LCD_FOURTH_ROW | Move cursor to the 4th row |
_LCD_CLEAR | Clear display |
_LCD_RETURN_HOME | Return cursor to home position, returns a shifted display to its original position. Display data RAM is unaffected. |
_LCD_CURSOR_OFF | Turn off cursor |
_LCD_UNDERLINE_ON | Underline cursor on |
_LCD_BLINK_CURSOR_ON | Blink cursor on |
_LCD_MOVE_CURSOR_LEFT | Move cursor left without changing display data RAM |
_LCD_MOVE_CURSOR_RIGHT | Move cursor right without changing display data RAM |
_LCD_TURN_ON | Turn Lcd display on |
_LCD_TURN_OFF | Turn Lcd display off |
_LCD_SHIFT_LEFT | Shift display left without changing display data RAM |
_LCD_SHIFT_RIGHT | Shift display right without changing display data RAM |
Library Example
This example demonstrates how to communicate Lcd in 8-bit mode via the SPI module, using serial to parallel convertor MCP23S17.
Stellaris
program Spi_Lcd8 dim text as char[16] dim counter as byte ' Port Expander module connections dim SPExpanderRST as sbit at GPIO_PORTA_DATA0_bit dim SPExpanderCS as sbit at GPIO_PORTA_DATA1_bit dim SPExpanderRST_Direction as sbit at GPIO_PORTA_DIR0_bit dim SPExpanderCS_Direction as sbit at GPIO_PORTA_DIR1_bit ' End Port Expander module connections sub procedure Move_Delay() ' Function used for text moving Delay_ms(500) ' You can change the moving speed here end sub main: text = "mikroElektronika" ' Initialize SPI module used with PortExpander SPI0_Init() Spi_Lcd8_Config(0) ' Initialize LCD over SPI interface Spi_Lcd8_Cmd(_LCD_CLEAR) ' Clear display Spi_Lcd8_Cmd(_LCD_CURSOR_OFF) ' Turn cursor off Spi_Lcd8_Out(1,6, "mikroE") ' Print text to LCD, 1st row, 6th column Spi_Lcd8_Chr_CP("!") ' Append '!' Spi_Lcd8_Out(2,1, text) ' Print text to LCD, 2nd row, 1st column ' Spi_Lcd8_Out(3,1,'mikroE') ' For LCD with more than two rows ' Spi_Lcd8_Out(4,15,'mikroE') ' For LCD with more than two rows Delay_ms(2000) ' Moving text for counter = 0 to 3 ' Move text to the right 4 times Spi_Lcd8_Cmd(_LCD_SHIFT_RIGHT) Move_Delay() next counter while TRUE ' Endless loop for counter = 0 to 6 ' Move text to the left 7 times Spi_Lcd8_Cmd(_LCD_SHIFT_LEFT) Move_Delay() next counter for counter = 0 to 6 ' Move text to the right 7 times Spi_Lcd8_Cmd(_LCD_SHIFT_RIGHT) Move_Delay() next counter wend end.
STM32
program Spi_Lcd8 dim text as char[16] dim counter as byte ' Port Expander module connections dim SPExpanderRST as sbit at GPIOB_ODR.B0 dim SPExpanderCS as sbit at GPIOB_ODR.B1 ' End Port Expander module connections sub procedure Move_Delay() ' Function used for text moving Delay_ms(500) ' You can change the moving speed here end sub main: text = "mikroElektronika" ' Initialize SPI module used with PortExpander SPI1_Init_Advanced(_SPI_FPCLK_DIV4, _SPI_MASTER or _SPI_8_BIT or _SPI_CLK_IDLE_LOW or _SPI_FIRST_CLK_EDGE_TRANSITION or _SPI_MSB_FIRST or _SPI_SS_DISABLE or _SPI_SSM_ENABLE or _SPI_SSI_1, @_GPIO_MODULE_SPI1_PB345) GPIO_Alternate_Function_Enable(@_GPIO_MODULE_SWJ_JTAGDISABLE) Spi_Lcd8_Config(0) ' Initialize LCD over SPI interface Spi_Lcd8_Cmd(_LCD_CLEAR) ' Clear display Spi_Lcd8_Cmd(_LCD_CURSOR_OFF) ' Turn cursor off Spi_Lcd8_Out(1,6, "mikroE") ' Print text to LCD, 1st row, 6th column Spi_Lcd8_Chr_CP("!") ' Append '!' Spi_Lcd8_Out(2,1, text) ' Print text to LCD, 2nd row, 1st column ' Spi_Lcd8_Out(3,1,'mikroE') ' For LCD with more than two rows ' Spi_Lcd8_Out(4,15,'mikroE') ' For LCD with more than two rows Delay_ms(2000) ' Moving text for counter = 0 to 3 ' Move text to the right 4 times Spi_Lcd8_Cmd(_LCD_SHIFT_RIGHT) Move_Delay() next counter while TRUE ' Endless loop for counter = 0 to 6 ' Move text to the left 7 times Spi_Lcd8_Cmd(_LCD_SHIFT_LEFT) Move_Delay() next counter for counter = 0 to 6 ' Move text to the right 7 times Spi_Lcd8_Cmd(_LCD_SHIFT_RIGHT) Move_Delay() next counter wend end.
What do you think about this topic ? Send us feedback!